249 research outputs found

    Nucleation and growth of platelets in hydrogen-ion-implanted silicon

    Get PDF
    H ion implantation into crystalline Si is known to result in the precipitation of planar defects in the form of platelets. Hydrogen-platelet formation is critical to the process that allows controlled cleavage of Si along the plane of the platelets and subsequent transfer and integration of thinly sliced Si with other substrates. Here we show that H-platelet formation is controlled by the depth of the radiation-induced damage and then develop a model that considers the influence of stress to correctly predict platelet orientation and the depth at which platelet nucleation density is a maximum. © 2005 American Institute of Physics

    An In Vitro Study of the Intervertebral Disc Structure Using 3 T Magnetic Resonance Imaging

    Get PDF
    Study Design. An in vitro magnetic resonance imaging (MRI) study. Objective. Investigate the potential of high-field MRI for producing higher quality images of the intervertebral disc (IVD) to better distinguish structural details. Summary of Background Data. Higher spatial and contrast resolution are important advantages when imaging the complex tissue structures in the spine such as the IVDs. However, at present it is challenging to capture the substructural details in the IVD such as the lamellae. Methods. Three MRI sequences; two-dimensional proton-density-weighted Turbo-Spin-Echo (PD-TSE), 2D T2-weighted Turbo-Spin-Echo (T2W-TSE) with fat-saturation (FS), and 3D Spoiled-Gradient-Echo (3D-GE), were modified based on the image quality and scan duration. IVDs of three intact cadaveric lumbar-spines (T12–S1, Age 83–94 yr) were imaged using these optimized sequences. Thereafter each IVD was transversely sectioned and the exposed surfaces were photographed. Landmark observations from corresponding MRI slices and photographs were compared to confirm the MRI captured morphology. The image quality was evaluated using signal-to-noise ratio (SNR), and relative-contrast values. Finally, the underlying tissue structures, including specific pathological features, were qualitatively compared between the MR images and photographs. Results. Observations from photographs and corresponding MRI slices matched well. The PD-TSE sequence had better overall SNR, but the relative contrast between the tissue types was relatively poor. The 3D-GE sequence had higher relative contrast between the IVD and bone, but not between annulus and nucleus regions. The T2W images provided the best relative contrast between the annulus and nucleus, however the standard deviations here were high. Structural details including fissures, vascular and granular tissue proliferation, and pathologies in the endplate region, were identifiable from the MR images obtained using the optimized sequences. Conclusion. The results demonstrate the potential of high-field MRI to capture the IVD structural details. Since the acquisition durations were within clinically acceptable levels, these methodological improvements have the potential to enhance clinical diagnostics

    Normal values and test–retest variability of stimulated-echo diffusion tensor imaging and fat fraction measurements in the muscle

    Get PDF
    OBJECTIVES: To assess the test–retest variability of both diffusion parameters and fat fraction (FF) estimates in normal muscle, and to assess differences in normal values between muscles in the thigh. METHODS: 29 healthy volunteers (mean age 37 years, range 20–60 years, 17/29 males) completed the study. Magnetic resonance images of the mid-thigh were acquired using a stimulated echo acquisition mode-echoplanar imaging (STEAM-EPI) imaging sequence, to assess diffusion, and 2-point Dixon imaging, to assess FF. Imaging was repeated in 19 participants after a 30 min interval in order to assess test–retest variability of the measurements. RESULTS: Intraclass correlation coefficients (ICCs) for test–retest variability were 0.99 [95% confidence interval, (CI): 0.98, 1] for FF, 0.94 (95% CI: 0.84, 0.97) for mean diffusivity and 0.89 (95% CI: 0.74, 0.96) for fractional anisotropy (FA). FF was higher in the hamstrings than the quadriceps by a mean difference of 1.81% (95% CI:1.63, 2.00)%, p < 0.001. Mean diffusivity was significantly lower in the hamstrings than the quadriceps (0.26 (0.13, 0.39) x10- 3 mm2s−1, p < 0.001) whereas fractional anisotropy was significantly higher in the hamstrings relative to the quadriceps with a mean difference of 0.063 (0.05, 0.07), p < 0.001. CONCLUSIONS: This study has shown excellent test-retest, variability in MR-based FF and diffusion measurements and demonstrated significant differences in these measures between hamstrings and quadriceps in the healthy thigh. ADVANCES IN KNOWLEDGE: Test–retest variability is excellent for STEAM-EPI diffusion and 2-point Dixon-based FF measurements in the healthy muscle. Inter- and intraobserver variability were excellent for region of interest placement for STEAM-EPI diffusion and 2-point Dixon-based FF measurements in the healthy muscle. There are significant differences in FF and diffusion measurements between the hamstrings and quadriceps in the normal muscle

    Diffusion Tensor Imaging for Diagnosing Root Avulsions in Traumatic Adult Brachial Plexus Injuries: A Proof-of-Concept Study

    Get PDF
    Cross-sectional MRI has modest diagnostic accuracy for diagnosing traumatic brachial plexus root avulsions. Consequently, patients either undergo major exploratory surgery or months of surveillance to determine if and what nerve reconstruction is needed. This study aimed to develop a diffusion tensor imaging (DTI) protocol at 3 Tesla to visualize normal roots and identify traumatic root avulsions of the brachial plexus. Seven healthy adults and 12 adults with known (operatively explored) unilateral traumatic brachial plexus root avulsions were scanned. DTI was acquired using a single-shot echo-planar imaging sequence at 3 Tesla. The brachial plexus was visualized by deterministic tractography. Fractional anisotropy (FA) and mean diffusivity (MD) were calculated for injured and avulsed roots in the lateral recesses of the vertebral foramen. Compared to healthy nerves roots, the FA of avulsed nerve roots was lower (mean difference 0.1 [95% CI 0.07, 0.13]; p < 0.001) and the MD was greater (mean difference 0.32 × 10−3 mm2/s [95% CI 0.11, 0.53]; p < 0.001). Deterministic tractography reconstructed both normal roots and root avulsions of the brachial plexus; the negative-predictive value for at least one root avulsion was 100% (95% CI 78, 100). Therefore, DTI might help visualize both normal and injured roots of the brachial plexus aided by tractography. The precision of this technique and how it relates to neural microstructure will be further investigated in a prospective diagnostic accuracy study of patients with acute brachial plexus injuries

    Penicillium menonorum, a new species related to P. pimiteouiense

    Get PDF
    Penicillium menonorum is described as a new monoverticillate, non-vesiculate species that resembles P. restrictum and P. pimiteouiense. On the basis of phylogenetic analysis of DNA sequences from four loci, P. menonorum occurs in a clade with P. pimiteouiense, P. vinaceum, P. guttulosum, P. rubidurum, and P. parvum. Genealogical concordance analysis was applied to P. pimiteouiense and P. parvum, substantiating the phenotypically defined species. The species P. rubidurum, P. guttulosum, and P. menonorum were on distinct branches statistically excluded from inclusion in other species and have distinct phenotypes

    A non-destructive method to distinguish the internal constituent architecture of the intervertebral discs using 9.4 Tesla Magnetic Resonance Imaging

    Get PDF
    Study Design: An in-vitro study of the intervertebral disc (IVD) structure using 9.4T Magnetic Resonance Imaging (MRI). Objective: Investigate the potential of ultra-high-field strength MRI for higher quality 3D volumetric MRI data-sets of the IVD to better distinguish structural details. Summary of Background Data: MRI has the advantages of being non-destructive and three dimensional in comparison to most techniques used to obtain the structural details of biological tissues, however its poor image quality at higher resolution is a limiting factor. Ultra-high-field MRI could improve the imaging of biological tissues but the current understanding of its application for spinal tissue is limited. Methods: Two ovine spinal segments (C7T1, T2T3) containing the IVD were separately imaged using two sequences; 3D-Spin-Echo (multislice-multiecho) pulse sequence for the C7T1 sample and 3D-Gradient-Echo (Fast-Low-Angle-Shot) pulse sequence for the T2T3 sample. The C7T1 sample was subsequently decalcified and imaged again using the same scanning parameters. Histological sections obtained from the decalcified sample were stained followed by digital scanning. Observations from corresponding MRI slices and histological sections were compared as a method of confirmation of morphology captured under MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative-contrast values were calculated for quantitative evaluation of image quality. Results: Measurements from histology sections and corresponding MRI slices matched well. Both sequences revealed finer details of the IVD structure. Under the spin-echo sequence, the annulus lamellae architecture was distinguishable and the SNR and CNR values were higher. The relative contrast was considerably higher between high (nucleus) and low (bone) signal constituents, but between the nucleus and the annulus the relative contrast was low. Under the gradient echo sequence, although the relative contrasts between constituents were poor, the fibre orientation was clearly manifested. Conclusions: The obtained positive results demonstrate the potential of ultra-high-field strength MRI to non-destructively capture the IVD structure

    Childhood socioeconomic position and objectively measured physical capability levels in adulthood: a systematic review and meta-analysis

    Get PDF
    &lt;p&gt;&lt;b&gt;Background:&lt;/b&gt; Grip strength, walking speed, chair rising and standing balance time are objective measures of physical capability that characterise current health and predict survival in older populations. Socioeconomic position (SEP) in childhood may influence the peak level of physical capability achieved in early adulthood, thereby affecting levels in later adulthood. We have undertaken a systematic review with meta-analyses to test the hypothesis that adverse childhood SEP is associated with lower levels of objectively measured physical capability in adulthood.&lt;/p&gt; &lt;p&gt;&lt;b&gt;Methods and Findings:&lt;/b&gt; Relevant studies published by May 2010 were identified through literature searches using EMBASE and MEDLINE. Unpublished results were obtained from study investigators. Results were provided by all study investigators in a standard format and pooled using random-effects meta-analyses. 19 studies were included in the review. Total sample sizes in meta-analyses ranged from N = 17,215 for chair rise time to N = 1,061,855 for grip strength. Although heterogeneity was detected, there was consistent evidence in age adjusted models that lower childhood SEP was associated with modest reductions in physical capability levels in adulthood: comparing the lowest with the highest childhood SEP there was a reduction in grip strength of 0.13 standard deviations (95% CI: 0.06, 0.21), a reduction in mean walking speed of 0.07 m/s (0.05, 0.10), an increase in mean chair rise time of 6% (4%, 8%) and an odds ratio of an inability to balance for 5s of 1.26 (1.02, 1.55). Adjustment for the potential mediating factors, adult SEP and body size attenuated associations greatly. However, despite this attenuation, for walking speed and chair rise time, there was still evidence of moderate associations.&lt;/p&gt; &lt;p&gt;&lt;b&gt;Conclusions:&lt;/b&gt; Policies targeting socioeconomic inequalities in childhood may have additional benefits in promoting the maintenance of independence in later life.&lt;/p&gt

    Intravital FRAP Imaging using an E-cadherin-GFP Mouse Reveals Disease- and Drug-Dependent Dynamic Regulation of Cell-Cell Junctions in Live Tissue.

    Full text link
    E-cadherin-mediated cell-cell junctions play a prominent role in maintaining the epithelial architecture. The disruption or deregulation of these adhesions in cancer can lead to the collapse of tumor epithelia that precedes invasion and subsequent metastasis. Here we generated an E-cadherin-GFP mouse that enables intravital photobleaching and quantification of E-cadherin mobility in live tissue without affecting normal biology. We demonstrate the broad applications of this mouse by examining E-cadherin regulation in multiple tissues, including mammary, brain, liver, and kidney tissue, while specifically monitoring E-cadherin mobility during disease progression in the pancreas. We assess E-cadherin stability in native pancreatic tissue upon genetic manipulation involving Kras and p53 or in response to anti-invasive drug treatment and gain insights into the dynamic remodeling of E-cadherin during in situ cancer progression. FRAP in the E-cadherin-GFP mouse, therefore, promises to be a valuable tool to fundamentally expand our understanding of E-cadherin-mediated events in native microenvironments

    The Distances of the Magellanic Clouds

    Get PDF
    The present status of our knowledge of the distances to the Magellanic Clouds is evaluated from a post-Hipparcos perspective. After a brief summary of the effects of structure, reddening, age and metallicity, the primary distance indicators for the Large Magellanic Cloud are reviewed: The SN 1987A ring, Cepheids, RR Lyraes, Mira variables, and Eclipsing Binaries. Distances derived via these methods are weighted and combined to produce final "best" estimates for the Magellanic Clouds distance moduli.Comment: Invited review article to appear in ``Post Hipparcos Cosmic Candles'', F. Caputo & A. Heck (Eds.), Kluwer Academic Publ., Dordrecht, in pres

    Oncogenic BRAF, unrestrained by TGFβ-receptor signalling, drives right-sided colonic tumorigenesis.

    Get PDF
    Right-sided (proximal) colorectal cancer (CRC) has a poor prognosis and a distinct mutational profile, characterized by oncogenic BRAF mutations and aberrations in mismatch repair and TGFβ signalling. Here, we describe a mouse model of right-sided colon cancer driven by oncogenic BRAF and loss of epithelial TGFβ-receptor signalling. The proximal colonic tumours that develop in this model exhibit a foetal-like progenitor phenotype (Ly6a/Sca1+) and, importantly, lack expression of Lgr5 and its associated intestinal stem cell signature. These features are recapitulated in human BRAF-mutant, right-sided CRCs and represent fundamental differences between left- and right-sided disease. Microbial-driven inflammation supports the initiation and progression of these tumours with foetal-like characteristics, consistent with their predilection for the microbe-rich right colon and their antibiotic sensitivity. While MAPK-pathway activating mutations drive this foetal-like signature via ERK-dependent activation of the transcriptional coactivator YAP, the same foetal-like transcriptional programs are also initiated by inflammation in a MAPK-independent manner. Importantly, in both contexts, epithelial TGFβ-receptor signalling is instrumental in suppressing the tumorigenic potential of these foetal-like progenitor cells
    corecore